A Visual Understanding of Steam Induced Water Hammer


When improperly drained of condensate in a high pressure steam main fills with condensate and completely surrounds the steam, an implosion takes place causing devastating water hammer.

Draining condensate and keeping it away from the steam by using proper steam trapping equipment will prevent this from happening.

The following video, courtesy of TLV, dramatically demonstrates the principle behind water hammer and its potentially devastating effects.

Swanson Flo
https://swansonflo.com
800-288-7926

Flowserve Valves - Kammer Control Valves

Kammer Control ValvesFLOWSERVE Kämmer manufactures special application and general service control valves and actuators, which are used extensively in the chemical, petrochemical, power, petroleum, pulp & paper, pharmaceutical, food processing and cryogenic industries.

FLOWSERVE Kämmer pneumatic actuators are widely known for their versatile diaphragm design, easy installation and simplified maintenance. When compared to other manufacturers’ diaphragm actuator designs, Kämmer actuators have much higher thrust capabilities, feature a very compact design and are lighter in weight. They also feature a field reversible design that requires no additional parts.

Download the Kammer Control Valve Product Profile Here

Mounting the Logix 3800 Digital Positioner on the Valtek Mark One Linear Control Valve


Compatible with linear and rotary valves and actuators, the Logix 3800 digital positioner offers industry-leading embedded measurement, data reduction and diagnostic functionalities. It  features powerful diagnostics that identify field problems and expedite corrective actions to ensure reduced return-to-operation times.

The Valtek Mark One globe control valve offers superior performance in liquid and gaseous services, while also permitting easy, fast and inexpensive maintenance.

This video details how to mount the Logix 3800 positioner on the Mark One valve.

For more information about Flowserve valve and valve automation products, contact Swanson Flo by calling 800-288-7926 or visit their website at https://swansonflo.com.

Happy New Year from Swanson Flo


Understanding Cavitation in Valves

Download the Flowserve Cavitation document here.

According to Wikipedia, "Cavitation is the formation of vapor cavities in a liquid, small liquid-free zones ("bubbles" or "voids"), that are the consequence of forces acting upon the liquid. It usually occurs when a liquid is subjected to rapid changes of pressure that cause the formation of cavities in the liquid where the pressure is relatively low. When subjected to higher pressure, the voids implode and can generate an intense shock wave."

Cavitation presents serious concerns to engineers and specifiers of  control valves. Understanding ways to mitigate cavitation is important. Flowserve has put together this excellent document on understanding cavitation and offers solutions on reducing or eliminating its effects.

Comprehensive Steam in Place (SIP) Whitepaper Available

Steriflow, a manufacturer of high purity control valves, pressure regulators, piping specialties, and steam specialties has authored a comprehensive overview of SIP, including existing components, piping design, and the new technology used to reduce common problem occurrences.

What are the rules and common piping practices employed to ensure that steam sterilization occurs on time without fail? What are SIP temperature validation alarms, or faults? Why do they occur? How does thermostatic steam trap operation affect the occurrence of temperature validation faults? What new technologies are available to mitigate common SIP problems? Specific answers to these questions will be covered in this white paper.

Get your copy of the "Steam in Place (SIP)" whitepaper here.

Table of Contents:
  • What Is SIP?
  • Fundamentals Of Process Equipment Steam Sterilization
  • Sanitary Balanced Port Thermostatic Steam Trap Operation
  • Validation Temperature Alarms Caused By High Subcooling Trap Operation
  • Problem Remediation
  • What Is A Sanitary Subcooled Condenser?
  • The SSC Series Explained Special SIP Applications For Large Vessels
  • Special SIP Applications: Conventional SIP Process Design For Larger Vessels
  • Special SIP Applications: Problems With Conventionally Designed SIP Drains For Large Vessels
  • Special SIP Applications: New Solution For SIP Design For Larger Vessels
Swanson Flo
800-288-7926 

Differential Pressure Gauge Designed for Harsh Environments

Ashcroft F5509/F6509
Ashcroft F5509/F6509
The Ashcroft F5509/F6509 differential pressure gauges are used for monitoring differential pressure between two separate pressure sources. Designed for harsh environments, these models provide high reliability and safety. A perfect solution for challenging application and installation requirements.

The F5509/F6509 differential gauges are ideal where safe and reliable pressure measurement is essential:

Process Control Markets:
  • Refineries 
  • Chemical and Petrochemical Plants
  • Water and Wastewater Pressure Control
  • Mining and Metals
  • Filter, Level and Flow Measurement
For more information about any Ashcroft product, contact Swanson Flo by calling 800-288-7926 or by visiting https://swansonflo.com.